Products https://sumitomoelectriclightwave.com Next Generation Thinking Thu, 15 Jan 2026 14:45:41 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.4 https://sumitomoelectriclightwave.com/wp-content/uploads/2019/08/fav.png Products https://sumitomoelectriclightwave.com 32 32 V-Groove Kits https://sumitomoelectriclightwave.com/product/v-groove-kits/ Tue, 13 Jan 2026 02:35:10 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=18335

Applicable

V-Groove KitQ102-M12+Quantum-Ultra Ribbon
SVG01-1220CompatibleCompatible
SVG01-1225CompatibleCompatible
SVG01-1620Non-CompatibleCompatible
SVG01-0100CompatibleCompatible

Ordering Information

Part NumberDescription
SVG01-1220Replacement V-Groove Block kit for 12 fibers 200μm splicing, includes V-Groove Block, Preconditioned ER-10-200 Electrodes with holders, Pair of FHM-12N Fiber Holders, Case​
SVG01-1225Replacement V-Groove Block kit for 12 fibers 250μm splicing, includes V-Groove Block, Preconditioned ER-10 Electrodes with holders, Pair of FHM-12V Fiber Holders, Case
SVG01-1620Replacement V-Groove Block kit for 16 fibers 200μm splicing, includes V-Groove Block, Preconditioned ER-10 Electrodes with holders, Pair of FHM-16N Fiber Holders, Case
SVG01-0100Replacement V-Groove Block kit for single fiber splicing, includes V-Groove Block, Preconditioned ER-10 Electrodes with holders, Pair of FHM-09 Fiber Holders, Case
]]>
(APAC Region Only) Freeform Ribbon™ Conventional OSP Nylon Sheath All-Dielectric Slotted Core Cables https://sumitomoelectriclightwave.com/product/freeform-ribbon-conventional-osp-nylon-sheath-all-dielectric-slotted-core-cables/ Sun, 11 Aug 2024 01:32:11 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=16502

Specifications

General
Region AvailabilityAPAC Region Only
ApplicationOutside Plant
Jacket ColorAqua
Cable StructureSlotted Core
Ribbon TypeFreeform Ribbon™
Metallic ElementsNo Bonding/Grounding Required
Fiber
Fiber TypePureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Bend Radius
During Installation20 x Cable OD
Mechanical Characteristics
Max. Tensile Load (During Installation)600 lb (2,670 N)
Max. Recommended Service Load180 lb (800 N)
Compression Resistance124 lb/in (220 N/cm)
Temperature Range
Operation+14°F to +158°F (-10°C to +70°C)
Standards
StandardsReferencing EIA/TIA-455

Ordering Information

SEI Part NumberFiber SizeFiber CountNominal Cable ODNominal WeightFibers Per RibbonFiber Per SlotStrandingStrength Member
INMMLB/KFTKG/KM
NM432SM(PA)-
SZ12(EZB)-WB-E/NY{LB}
250 μm432f0.8321.0201.6300.012f72SZFRP
NM1728SM(PA)-
TS12-WB-E/NY{LB}
250 μm1,728f1.1429.0470.4700.012f288HLFRP
NM288SM(PA200)-
SZ12(EZB)-WB-E/NY{LB}
200 μm288f0.6316.0147.8220.012f48SZFRP
NM432SM(PA200)-
SZ12(EZB)-WB-E/NY{LB}
200 μm432f0.6917.5181.4270.012f72SZFRP
NM864SM(PA200)-
SZ12(EZB)-WB-E/NY{LB}
200 μm864f0.7920.0255.3380.012f144SZFRP
NM1728SM(PA200)-
SZ12(EZB)-WB-E/NY{LB}
200 μm1,728f1.0627.0315.8470.012f288SZFRP

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
ACS-01Armored Cable Slit & Ring Tool, 0.315 – 1.125 in (8 – 28.6 mm) for End/Mid-Span Access
ACS-01-BLADEReplacement Blade for ACS-01
FRSJ-01Freeform Ribbon™ Separation Tool Kit
MA-2-REFILLRibbon Matrix Remover with Board & Double-Sided Tape (Qty. 25)
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and up to 3 mm Jacketed Single Fibers

]]>
(APAC Region Only) Freeform Ribbon™ Conventional OSP Slotted Core Cables  https://sumitomoelectriclightwave.com/product/freeform-ribbon-osp-slotted-core-cables/ Sun, 11 Aug 2024 19:21:15 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=16512

Specifications

General
Region AvailabilityAPAC Region Only
ApplicationOutside Plant
Jacket ColorBlack
Cable StructureSlotted Core
Ribbon TypeFreeform Ribbon™
Metallic ElementsNo Bonding/Grounding Required
Fiber
Fiber TypePureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Bend Radius
During Installation20 x Cable OD
Mechanical Characteristics
Max. Tensile Load (During Installation)600 lb (2,670 N)
Max. Recommended Service Load180 lb (800 N)
Compression Resistance124 lb/in (220 N/cm)
Temperature Range
Operation-40°F to +158°F (-40°C to +70°C)
Standards
StandardsReferencing EIA/TIA-455

Ordering Information

Part NumberFiber SizeFiber CountNominal Cable ODNominal WeightFibers Per RibbonFiber Per SlotStrandingStrength Member
SELSEIINMMLB/KFTKG/KM
N/A288SM(PA200)-
SZ12(EZB)-WB-E
200 μm288f0.5614.2117.6175.012f48SZMetallic
DRSC-OSP6-SA00288-
200-ADEROLD
NM288SM(PA200)-
SZ12(EZB)-WB-E
200 μm288f0.6015.0127.7190.012f48SZFRP
DRSC-OSP6-SA00432-
200-ADEROLD
NM432SM(PA200)-
SZ12(EZB)-WB-E
200 μm432f0.6516.5134.4200.012f72SZFRP
DRSC-OSP6-SA00864-
200-ADE
NM864SM(PA200)-
SZ12(EZB)-WB-E
200 μm864f0.7519.0201.6300.012f144SZFRP
DRSC-OSP6-SA01728-
200-ADE
NM1728SM(PA200)-
SZ12(EZB)-WB-E
200 μm1,728f0.9925.0268.8400.012f288SZFRP

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
ACS-01Armored Cable Slit & Ring Tool, 0.315 – 1.125 in (8 – 28.6 mm) for End/Mid-Span Access
ACS-01-BLADEReplacement Blade for ACS-01
FRSJ-01Freeform Ribbon™ Separation Tool Kit
MA-2-REFILLRibbon Matrix Remover with Board & Double-Sided Tape (Qty. 25)
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and up to 3 mm Jacketed Single Fibers

]]>
(APAC Region Only) Freeform Ribbon™ Indoor/Outdoor LSZH Slotted Core Cables https://sumitomoelectriclightwave.com/product/freeform-ribbon-indoor-outdoor-lszh-slotted-core-cables/ Sun, 11 Aug 2024 19:40:16 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=16514

Specifications

General
Region AvailabilityAPAC Region Only
ApplicationOutside Plant
Jacket ColorBlack
Cable StructureSlotted Core
Ribbon TypeFreeform Ribbon™
Metallic ElementsNo Bonding/Grounding Required
Fiber
Fiber TypePureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Bend Radius
During Installation20 x Cable OD
Mechanical Characteristics
Max. Tensile Load (During Installation)600 lb (2,670 N)
Max. Recommended Service Load180 lb (800 N)
Compression Resistance124 lb/in (220 N/cm)

Ordering Information

SEI Part NumberFiber SizeFiber CountNominal Cable ODNominal WeightFibers Per RibbonFiber Per SlotStrandingStrength MemberStandards
INMMLB/KFTKG/KM
NM864SM(PA)-TS12(EZB)-
WB-E-LSZH(EN)
250 μm864f0.8922.5295.7440.012f144HLFRPIEC 60332-3
Part 3 Cat.C
EN50399
NM1728SM(PA)-TS12(EZB)-
WB-E-LSZH(EN)
250 μm1,728f1.1128.0403.2600.012f288HLFRPIEC 60332-3
Part 3 Cat.C
EN50399
NM288SM(PA200)-SZ12(EZB)-
WB-E-LSZH
200 μm288f0.6516.5168.0250.012f48SZFRPIEC 60332-3
Part 3 Cat.C
IEC 61034-2
288SM(PA200)-SZ12(EZB)-
WB-E-LSZH
200 μm288f0.6115.5164.7245.012f48SZMetallicIEC 60332-3
Part 3 Cat.C
IEC 61034-2
432SM(PA200)-SZ12(EZB)-
WB-E-FR
200 μm432f0.6917.5221.7330.012f72SZMetallicJIS C 3521N/A
NM1728SM(PA200)-TS12(EZB)-
WB-E-LSZH(EN)
200 μm1,728f0.9724.5309.1460.012f288HLFRPIEC 60332-3
Part 3 Cat.C
EN50399

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
ACS-01Armored Cable Slit & Ring Tool, 0.315 – 1.125 in (8 – 28.6 mm) for End/Mid-Span Access
ACS-01-BLADEReplacement Blade for ACS-01
FRSJ-01Freeform Ribbon™ Separation Tool Kit
MA-2-REFILLRibbon Matrix Remover with Board & Double-Sided Tape (Qty. 25)
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and up to 3 mm Jacketed Single Fibers

]]>
Freeform Ribbon™ Indoor/Outdoor X-Slotted Core Cable https://sumitomoelectriclightwave.com/product/freeform-ribbon-indoor-outdoor-x-slotted-core-cable/ Tue, 05 Nov 2024 11:23:29 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=17163

Specifications

General
ApplicationIndoor/Outdoor
Jacket ColorBlack
Jacket MaterialFlame Retardant Polyethylene (FRPE)
Cable StructureSlotted Core
Ribbon TypeFreeform Ribbon™
Metallic ElementsBonding / Grounding Required
Fiber
Fiber TypePureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Maximum Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Mechanical Characteristics
Maximum Tensile Load (During Installation)600 lb (2,670 N)
Maximum Recommended Service Load180 lb (800 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Bend Radius
During Installation (Dynamic)20 x Cable OD
After Installation (Static)12.5 x Cable OD
Temperature Range
Operation-40°F to +158°F (-40°C to +70°C)
Standards
StandardsOFNR, UL 1666

Ordering Information

Part NumberFiber CountNominal Cable ODNominal WeightNo. of SlotsFiber Per BundleFibers Per SlotStrength Member
INLB/KFTLBS/KFTKG/KM
200 μm
SE-8GGT6912-B-M6,912f1.3033.0655.0975.04288f1,728fFRP

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
FRSJ-01Freeform Ribbon™ Separation Tool Kit
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and up to 3 mm Jacketed Single Fibers
LYNX-SHEARSLynx-CustomFit™ Aramid Shears

]]>
Freeform Ribbon™ Outdoor/Indoor OFNR LSZH Monotube Cables https://sumitomoelectriclightwave.com/product/freeform-ribbon-outdoor-indoor-ofnr-lszh-monotube-cables/ Thu, 08 Jan 2026 22:51:29 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=18308

Specifications

General
ApplicationOutdoor/Indoor
Jacket ColorBlack
Cable StructureMonotube™
Ribbon TypeFreeform Ribbon™
Metallic ElementsNo Bonding/Grounding Required
Fiber
Fiber TypePureBand™-R G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Maximum Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Bend Radius
During Installation (Dynamic)20 x Cable O.D.
After Installation (Static)15 x Cable O.D.
Mechanical Characteristics
Max. Tensile Load (During Installation)600 lb (2,670 N)
Max. Recommended Service Load180 lb (800 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Temperature Range
Operation-40°F to +158°F (-40°C to +70°C)
Storage & Shipping-40°F to +158°F (-40°C to +70°C)
Installation+14°F to +140°F (-10°C to +60°C)
Standards
StandardsOFNR, FT4, Low Smoke/ST-1

Ordering Information

Part NumberFiber CountNominal Cable O.D.Nominal WeightFibers Per RibbonFibers Per BundleNo. of Bundles
INMMLBS/KFTKG/KM
200μm
SE-8BST0288-B288f0.5413.8107.8160.412f72f4
SE-8BST0864-B864f0.6917.6166.0247.112f72f12

Accessories

Part NumberDescription
CRC-001 Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
FRSJ-01Freeform Ribbon™ Separation Tool Kit
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and up to 3 mm Jacketed Single Fibers
FOS-01Lynx-CustomFit™ Fiber Optic Shears

]]>
Freeform Ribbon™ All-Dielectric Monotube OSP Cable https://sumitomoelectriclightwave.com/product/freeform-ribbon-all-dielectric-monotube-osp-cable/ Sun, 30 Jun 2024 23:10:42 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=16386

Specifications

General
ApplicationOutside Plant
Jacket ColorBlack
Cable StructureMonotube™
Ribbon TypeFreeform Ribbon™
Metallic ElementsNo Bonding/Grounding Required
Fiber
Fiber Type (96f to 864f Only)PureBand™-R G.657.A1 Bend Insensitive Single-Mode Fiber
(Mode Field Diameter at 1310 nm: Typ. 9.2 μm)
Fiber Type (1728f Only)PureAccess® G.657.A1Bend Insensitive Single-Mode Fiber
(Mode Field Diameter at 1310 nm: Typ. 8.6 μm)
Fiber Attenuation GradesStandard Single-Mode
Maximum Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Bend Radius
During Installation (Dynamic)20 x Cable OD
After Installation (Static)15 x Cable OD
Mechanical Characteristics
Max. Tensile Load (During Installation)600 lb (2,670 N)
Max. Recommended Service Load180 lb (800 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Temperature Range
Operation-40°F to +158°F (-40°C to +70°C)
Storage & Shipping-40°F to +158°F (-40°C to +70°C)
Installation-22°F to +140°F (-30°C to +60°C)
Standards
StandardsReferencing Telcordia GR-20

Ordering Information

Part NumberFiber CountNominal Cable ODNominal WeightNo. of UnitFiber No. of Unit
INMMLB/KFTKG/KM
250μm
SE-CMDP0096-G-M96f0.4110.451.075.9
SE-CMDP0144-G-M144f0.4310.955.883.0272
SE-CMDP0288-G-M288f0.4712.083.0123.4372
SE-CMDP0432-G-M432f0.5313.5100.8150.0672
SE-CMDP0864-G-M864f0.7218.2145.1216.01272
SE-8MDP1728-G-M1,728f0.98 24.9246.0366.02472

Accessories

Part NumberDescription
CRC-001 Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
UCTS-001Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access
UCTS-001-BLADEReplacement Blade for UCTS-001
FRSJ-01Freeform Ribbon™ Separation Tool Kit
MA-2-REFILLRibbon Matrix Remover with Board & Double-Sided Tape (Qty. 25)
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and up to 3 mm Jacketed Single Fibers
LYNX-SHEARSLynx-CustomFit™ Aramid Shears

]]>
Freeform Ribbon™ Outdoor/Indoor LSZH Riser Monotube Cables (288f-1728f) https://sumitomoelectriclightwave.com/product/freeform-ribbon-outdoor-indoor-lszh-riser-monotube-cables-288f-1728f/ Mon, 17 Feb 2025 14:19:11 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=17538

Specifications

General
ApplicationOutdoor/Indoor
Jacket ColorBlack
Cable StructureMonotube™
Ribbon TypeFreeform Ribbon™
Metallic ElementsNo Bonding/Grounding Required
Fiber
Fiber TypePureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Maximum Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Mechanical Characteristics
Max. Tensile Load (During Installation)600 lb (2,670 N)
Max. Recommended Service Load180 lb (800 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Bend Radius
During Installation (Dynamic)20 x Cable O.D.
After Installation (Static)15 x Cable O.D.
Temperature Range
Operation-40 to +158°F (-40 to +70°C)
Storage & Shipping-40 to +158°F (-40 to +70°C)
Installation+14 to +140°F (-10 to +60°C)
Standards
StandardsICEA S-104-696, IEC 60794-6-10, UL 1666, UL 1685-LS

Ordering Information

Part NumberFiber SizeFiber CountNominal Cable OD
(IN | MM)
Nominal Weight
(LB/KFT | KG/KM)
Fibers per RibbonFibers per Bundle
SE-8MMT0288-B-NP200 μm288f0.50 (12.6)89 (133)12f72f
SE-8MMT0432-B-NP200 μm432f0.55 (13.9)102 (152)12f72f
SE-8MMT0864-B-NP200 μm864f0.69 (17.4)137 (205)12f72f
SE-8MMT1728-B-NP200 μm1,728f0.85 (21.6)275 (410)12f72f

Accessories

Part NumberDescription
CRC-001 Cable Ring Tool for End/Mid-Span Access; 0.25 – 1.625 in (4 – 28 mm)
CSC-002Cable Slit Tool for End/Mid-Span Access
FRSJ-01Freeform Ribbon™ Separation Tool Kit
JR-7Heated Jacket Remover with AC-Adapter & Battery for Single Fibers & up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250μm, 900μm, and up to 3mm Jacketed Single Fibers
LYNX-SHEARSLynx-CustomFit™ Aramid Shears

]]>
Freeform Ribbon™ Outdoor/Indoor LSZH Riser Monotube Cables (3456f) https://sumitomoelectriclightwave.com/product/freeform-ribbon-outdoor-indoor-lszh-riser-monotube-cables-3456f/ Mon, 17 Feb 2025 14:01:34 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=17536

Specifications

General
ApplicationOutdoor/Indoor
Jacket ColorBlack
Cable StructureMonotube™
Ribbon TypeFreeform Ribbon™
Metallic ElementsNo Bonding/Grounding Required
Fiber
Fiber TypePureAccess® G.657.A2 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Maximum Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Mechanical Characteristics
Max. Tensile Load (During Installation)600 lb (2,670 N)
Max. Recommended Service Load180 lb (800 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Bend Radius
During Installation (Dynamic)20 x Cable O.D.
After Installation (Static)15 x Cable O.D.
Temperature Range
Operation-40 to +158°F (-40 to +70°C)
Storage & Shipping-40 to +158°F (-40 to +70°C)
Installation+14 to +140°F (-10 to +60°C)
Standards
StandardsICEA S-104-696, IEC 60794-6-10, UL 1666, UL 1685-LS

Ordering Information

Part NumberFiber SizeFiber CountNominal Cable OD
(IN | MM)
Nominal Weight
(LB/KFT | KG/KM)
Fibers per RibbonFibers per Bundle
SE-AMMT3456-B-NP200 μm3,456f1.00 (25.4)397 (592)12f144f

Accessories

Part NumberDescription
CRC-001 Cable Ring Tool for End/Mid-Span Access; 0.25 – 1.625 in (4 – 28 mm)
CSC-002Cable Slit Tool for End/Mid-Span Access
FRSJ-01Freeform Ribbon™ Separation Tool Kit
JR-7Heated Jacket Remover with AC-Adapter & Battery for Single Fibers & up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250μm, 900μm, and up to 3mm Jacketed Single Fibers
LYNX-SHEARSLynx-CustomFit™ Aramid Shears

]]>
Freeform Ribbon™ Outdoor/Indoor LSZH Riser Monotube Cables https://sumitomoelectriclightwave.com/product/freeform-ribbon-outdoor-indoor-lszh-riser-monotube-cables/ Wed, 20 Nov 2024 13:12:42 +0000 https://sumitomoelectriclightwave.com/?post_type=product&p=17212

Specifications

General
ApplicationOutdoor/Indoor
Jacket ColorBlack
Cable StructureMonotube™
Ribbon TypeFreeform Ribbon™
Metallic ElementsNo Bonding/Grounding Required
Fiber
Fiber TypePureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Maximum Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
Mode Field Diameter1310 nm | 8.6 μm ± 0.4 μm
Mechanical Characteristics
Max. Tensile Load (During Installation)600 lb (2,670 N)
Max. Recommended Service Load180 lb (800 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Bend Radius
During Installation (Dynamic)20 x Cable O.D.
After Installation (Static)15 x Cable O.D.
Temperature Range
Operation-40 to +158°F (-40 to +70°C)
Storage & Shipping-40 to +158°F (-40 to +70°C)
Installation+14 to +140°F (-10 to +60°C)
Standards
StandardsOFNR, UL 1666, 1685-LS, ICEA 696

Ordering Information

Part NumberFiber SizeFiber CountNominal Cable OD
(IN | MM)
Nominal Weight
(LB/KFT | KG/KM)
Fibers per RibbonFibers per BundleCPR Rating
SE-8MMP0288-B250 μm288f0.57 (14.5)146 (218)12f72fCca, s1a, d2, a1

Accessories

Part NumberDescription
CRC-001 Cable Ring Tool for End/Mid-Span Access; 0.25 – 1.625 in (4 – 28 mm)
CSC-002Cable Slit Tool for End/Mid-Span Access
FRSJ-01Freeform Ribbon™ Separation Tool Kit
JR-7Heated Jacket Remover with AC-Adapter & Battery for Single Fibers & up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250μm, 900μm, and up to 3mm Jacketed Single Fibers
LYNX-SHEARSLynx-CustomFit™ Aramid Shears

]]>
Freeform Ribbon™ Flexible Indoor Plenum Cordage https://sumitomoelectriclightwave.com/product/freeform-ribbon-indoor-plenum-cord/ https://sumitomoelectriclightwave.com/product/freeform-ribbon-indoor-plenum-cord/#respond Fri, 15 Nov 2024 19:24:17 +0000 https://www.sumitomoelectric.com/?post_type=product&p=6358

Specifications

GENERAL
ApplicationIndoor
Jacket ColorYellow
Cable StructureInterconnect Cordage
Ribbon TypeFreeform Ribbon™
FIBER
Fiber TypePureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Maximum Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
MECHANICAL CHARACTERISTICS
Maximum Tensile Load During Installation50 lb (220 N)
Maximum Recommended Service Load15 lb (66 N)
Maximum Compression Resistance20 lb/in (35 N/cm)
BEND RADIUS
During Installation (Dynamic)20 x Cable OD
After Installation (Static)10 x Cable OD
TEMPERATURE RANGE
Operation+32 to +158°F (0 to +70°C)
Storage & Shipping-40 to +158°F (-40 to +70°C)
Installation+32 to +140°F (0 to +60°C)
STANDARDS
StandardsOFNP, FT6

Ordering Information

PART NUMBERFIBER COUNTNOMINAL CABLE OD 
(in | mm)
NOMINAL WEIGHT
(lb/kft | kg/km)
FIBERS PER RIBBONNO. OF BUNDLES
250μm
SE-8IUP0012-B-1212f0.10 (3.0)6.0 (8.9)12fN/A
SE-8IUP0024-B-1224f0.12 (3.0)6.0 (8.9)12fN/A
SE-8IUP0048-B-1248f0.15 (3.8)8.0 (11.9)12fN/A

Accessories

PART NUMBERDESCRIPTION
BTR-2Buffer Tube Slit & Ring Tool, 0.126 – 0.220 in (3.2 – 5.6 mm) for End/Mid-Span Access
BTS-TP1Buffer Tube Slit Tool, 0.071 – 0.126 in (1.8 – 3.2 mm) for End/Mid-Span Access
FRSJ-01Freeform Ribbon® Separation Tool Kit
JR-7Heated Jacket Remover with AC-Adapter & Battery for Single Fibers & up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250μm, 900μm, and up to 3mm Jacketed Single Fibers
LYNX-SHEARSLynx-CustomFit™ Aramid Shears
LYNX2-CORDTOOL-1.6-2.0-3.0Buffer Tube Slit & Ring Tool, 0.06 – 0.09 in (1.6 – 2.4 mm) for Lynx-CustomFit™ Cord Prep and End Access
LYNX2-CORDTOOL-2.0-3.0Buffer Tube Slit & Ring Tool, 0.08 – 0.12 in (2.0 – 3.0 mm) for Lynx-CustomFit™ Cord Prep and End Access
LYNX2-CORDTOOL-4.8Buffer Tube Slit & Ring Tool, 0.06 – 0.12 in (1.6 – 3.0 mm) for Lynx-CustomFit™ Cord Prep and End/Mid-Span Access
MA-2-REFILLRibbon Matrix Remover with Board & Double-Sided Tape (Qty. 25)
MSAT-01Buffer Tube Slit Tool, 0.12 – 0.26 in (2.9 – 6.8 mm) for End/Mid-Span Access, and Lynx-CustomFit™ Connectors
]]>
https://sumitomoelectriclightwave.com/product/freeform-ribbon-indoor-plenum-cord/feed/ 0
Freeform Ribbon™ Indoor LSZH Riser Central Tube Cables https://sumitomoelectriclightwave.com/product/freeform-ribbon-indoor-lszh-riser-central-tube-cables/ https://sumitomoelectriclightwave.com/product/freeform-ribbon-indoor-lszh-riser-central-tube-cables/#respond Wed, 15 Apr 2020 14:20:39 +0000 https://www.sumitomoelectric.com/?post_type=product&p=6300

Specifications

GENERAL
ApplicationIndoor
Jacket ColorYellow
Cable StructureCentral Tube
Ribbon TypeFreeform Ribbon™
FIBER
Fiber TypePureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
Fiber Attenuation GradesStandard Single-Mode
Maximum Attenuation1310 nm | 0.40 dB/km
1550 nm | 0.30 dB/km
BEND RADIUS
During Installation20 x Cable OD
After Installation10 x Cable OD
MECHANICAL CHARACTERISTICS
Maximum Tensile Load During Installation300 lb (1,340 N)
Maximum Recommended Service Load100 lb (450 N)
Compression Resistance125 lb/in (220 N/cm)
TEMPERATURE RANGE
Operation+32 to +158°F (0 to +70°C)
Storage & Shipping-40 to +158°F (-40 to +70°C)
Installation+32 to +140°F (0 to +60°C)
STANDARDS
StandardsOFNR, FT4, Low Smoke/ST-1

Ordering Information

PART NUMBERFIBER SIZEFIBER COUNTNOMINAL CABLE OD
(in | mm)
NOMINAL WEIGHT
(lb/kft | kg/km)
FIBERS PER RIBBONNO. OF BUNDLESCPR RATING
SE-8RZP0072-B-12250 μm72f0.46 in (11.8 mm)98.5 lb/kft (146.5 kg/km)12fN/AN/A
SE-8RNP0096-B-12250 μm96f0.46 in (11.8 mm)100.1 lb/kft (148.9 kg/km)12fN/ACca, s1a, d0, a1
SE-8RZP0144-B-12250 μm144f0.57 in (14.4 mm)129.1 lb/kft (192.1 kg/km)12fN/AN/A
SE-8RNP0192-B-12250 μm192f0.57 in (14.4 mm)132.3 lb/kft (196.9 kg/km)12fN/ACca, s1a, d0, a1
SE-8RZT864-B200 μm864f0.86 in (21.8 mm)268.4 lb/kft (399.4 kg/km)12f12N/A

Accessories

PART NUMBERDESCRIPTION
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
UCTS-001Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access
BTR-3Buffer Tube Slit & Ring Tool, 0.250 – 0.563 in (6.4 – 14.3 mm) for End/Mid-Span Access
UCTS-001-BLADEReplacement Blade for UCTS-001
FRSJ-01Freeform Ribbon™ Separation Tool Kit
MA-2-REFILLRibbon Matrix Remover with Board & Double-Sided Tape (Qty. 25)
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and Up to 3 mm Jacketed Single Fibers
LYNX-SHEARSLynx-CustomFit™ Aramid Shears

]]>