Standard Ribbon Central Tube Cables https://sumitomoelectriclightwave.com Next Generation Thinking Mon, 26 Jan 2026 02:24:05 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.4 https://sumitomoelectriclightwave.com/wp-content/uploads/2019/08/fav.png Standard Ribbon Central Tube Cables https://sumitomoelectriclightwave.com 32 32 Standard Ribbon Interlocking Armored Indoor Riser Central Tube Cables https://sumitomoelectriclightwave.com/product/indoor-interlocking-armored-riser-ribbon-cables-12-432f/ Thu, 29 Nov 2018 16:24:58 +0000 https://www.sumitomoelectric.com/?post_type=product&p=4705

Specifications

General
ApplicationIndoor
Cable StructureCentral Tube
Ribbon TypeStandard Ribbon
Metallic ElementsBonding/Grounding Required
Mechanical Characteristics
Maximum Tensile Load (During Installation)600 lb (2,670 N)
Maximum Recommended Service Load200 lb (890 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Bend Radius
During Installation (Dynamic)20 x Cable OD
After Installation (Static)10 x Cable OD
Temperature Range
Operation-4 to +158°F (-20 to +70°C)
Storage & Shipping-40 to +149°F (-40 to +65°C)
Installation-4 to +158°F (-20 to +70°C)
Standards
StandardsOFCR, FT4

Ordering Information

Fiber Count Fiber Size Nominal Cable OD (in | mm) Nominal Cable Armor OD (in | mm) Nominal Weight (lb/kft | kg/km) Fibers Per Ribbon
12 – 96f250 μm0.53 in (13.6 mm)0.91 in (23.0 mm)265.3 lb/kft (396.0 kg/km)12f
108 – 216f250 μm0.63 in (16.1 mm)0.98 in (25.0 mm)308.2 lb/kft (460.0 kg/km)12f
288 – 432f250 μm1.00 in (26.7 mm)1.13 in (28.9 mm)375.2 lb/kft (560.0 kg/km)24f
576 – 864f250 μm1.24 in (31.5 mm)1.35 in (34.4 mm)674.0 lb/kft (1,003.0 kg/km)36f

Instructions: Create an item number by using this character set & codes.

SE – [ 1 ] RL [ 2 2 2 2 ] – [ 3 ]

[ 1 ] – Fiber Type[ 2 ] – Fiber Count (4-Digits)[ 3 ] – Fiber Attenuation Grades
1 – 50 μm Multi-Mode Fiber (OM3/OM4, 12 – 432f Only)  
8 –  PureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
0012 – 12 Fibers
0024 – 24 Fibers
0048 – 48 Fibers
0072 – 72 Fibers
0096 – 96 Fibers
0144 – 144 Fibers
0192 – 192 Fibers
0216 – 216 Fibers
0288 – 288 Fibers
0432 – 432 Fibers
0576 – 576 Fibers
0864 – 864 Fibers
B – Standard Single-Mode 0.40/0.30 dB/km (1310/1550 nm)  
7 – OM3 Enhanced Performance 50 μm MM (850/1300 nm) 10 Gb
8 –  OM4 Enhanced Performance 50 μm MM (850/1300 nm) 10 Gb

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
ACS-01Armored Cable Slit & Ring Tool, 0.315 – 1.125 in (8 – 28.6 mm) for End/Mid-Span Access
UCTS-001Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access
ACS-01-BLADEReplacement Blade for ACS-01
UCTS-001-BLADEReplacement Blade for UCTS-001
MA-2-REFILLRibbon Matrix Remover with Board & Double Sided Tape (Qty. 25)
RS-2424f Ribbon Splitter Tool
JR-7Heated Jacket Remover with AC Adapter & Battery for Single-fibers & up to12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and Up to 3 mm Jacketed Single-fibers
FS01Lynx-CustomFit™ Fiber Optic Shears
]]>
Standard Ribbon Indoor Riser Central Tube Cables https://sumitomoelectriclightwave.com/product/indoor-rohs-riser-ribbon-cable/ Thu, 14 Jan 2016 21:06:44 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=372

Specifications

General
ApplicationIndoor
Cable StructureCentral Tube
Ribbon TypeStandard Ribbon
Metallic ElementsNo Bonding/Grounding Required
Mechanical Characteristics
Maximum Tensile Load (During Installation)600 lb (2,670 N)
Maximum Recommended Service Load200 lb (890 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Minimum Bend Radius (During/After Installation)20/10 x Cable O.D.
Temperature Range
Operation-4 to +158°F (-20 to +70°C)
Storage & Shipping+14 to +140°F (-10 to +60°C)
Installation-40 to +158°F (-40 to +70°C)
Standards
StandardsOFNR, FT4

Ordering Information

Fiber CountFiber SizeNominal Cable OD (in | mm)Nominal Weight (lb/kft | kg/km)Fibers Per Ribbon
12 – 96f250 μm0.52 (13.2)102.0 (151.0)12f
108 – 216f250 μm0.62 (15.7)128.0 (190.0)12f
288 – 432f250 μm0.81 (20.5)203.0 (302.0)24f
576 – 864f250 μm1.01 (25.6)319.0 (474.0)36f

Instructions: Create a part number by using this character set & codes.

SE – [ 1 ] RP [ 2 2 2 2 ] – [ 3 ]

[ 1 ] – Fiber Type[ 2 ] – Fiber Count (4-Digits)[ 3 ] – Fiber Attenuation Grades
1 – 50 μm Multi-mode Fiber (OM3/OM4, 12-432f Only)
2 – 50 μm Multi-mode Fiber (OM1, 12-432f Only)
8 –  PureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
0012 – 12f
0024 – 24f 
0048 – 48f 
0072 – 72f 
0096 – 96f 
0144 – 144f
0288 – 288f
0432 – 432f
0576 – 576f
0864 – 864f  
B – Standard Single-Mode 0.40/0.30 dB/km (1310/1550 nm)
7 – OM3 Enhanced performance 50 μm MM (850/1300nm) 10Gb
8 –  OM4 Enhanced performance 50 μm MM (850/1300nm) 10Gb
9 –  OM1 Enhanced performance 62.5 μm MM (850/1300nm) 10Gb

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
UCTS-001Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access
UCTS-001-BLADEReplacement Blade for UCTS-001
MA-2-REFILLRibbon Matrix Remover with Board & Double Sided Tape (Qty. 25)
RS-2424f Ribbon Splitter Tool
JR-7Heated Jacket Remover with AC Adapter & Battery for Single-fibers & up to12-Fiber Ribbons
JR-M03Jacket Remover for 250μm, 900μm, and Up to 3 mm Jacketed Single-fibers
FOS-01Lynx-CustomFit™ Fiber Optic Shears
]]>
Standard Ribbon Indoor Plenum Central Tube Cables https://sumitomoelectriclightwave.com/product/plenum-ribbon-cable/ Thu, 14 Jan 2016 21:05:59 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=370

Specifications

GENERAL
ApplicationIndoor
Cable StructureCentral Tube
Ribbon TypeStandard Ribbon
Metallic ElementsNo Bonding/Grounding Required
MECHANICAL CHARACTERISTICS
Maximum Tensile Load (During Installation)300 lb (1,335 N)
Maximum Recommended Service Load100 lb (445 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Minimum Bend Radius (During/After Installation)20 / 10 x Cable OD
TEMPERATURE RANGE
Operation+32 to +158°F (0 to +70°C)
Storage & Shipping-40 to +158°F (-40 to +70°C)
Installation+32 to +140°F (0 to +60°C)
STANDARDS
StandardsOFNP UL, FT-6/NFPA 262, ICEA 596

Ordering Information

Fiber CountNominal Cable O.D. (in | mm) Nominal Weight (lb/kft | kg/km)Fibers Per Ribbon
12 – 48f0.44 in (10.3 mm)87.0 lb/kft (130.0 kg/km)12f
60 – 96f0.55 in (14.0 mm)136.0 lb/kft (203.0 kg/km)12f
108 – 216f0.65 in (16.6 mm)171.0 lb/kft (255.0 kg/km)12f
288 – 432f0.85 in (21.6 mm)249.0 lb/kft (371.0 kg/km)24f

Instructions: Create a part number by using this character set & codes.

SE – [ 1 ] RU [ 2 2 2 2 ] – [ 3 ]

[ 1 ] – Fiber Type[ 2 ] – Fiber Count (4-Digits)[ 3 ] – Fiber Attenuation Grades
1 – 50μm Multi-mode Fiber (OM3/OM4)
2 – 50μm Multi-mode Fiber (OM1)
8 –  PureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber
0012 – 12 Fibers
0024 – 24 Fibers
0036 – 36 Fibers
0048 – 48 Fibers
0072 – 72 Fibers
0096 – 96 Fibers
0144 – 144 Fibers
0192 – 192 Fibers
0216 – 216 Fibers
0288 – 288 Fibers
0432 – 432 Fibers
B – Standard Single-Mode 0.40/0.30 dB/km (1310/1550 nm)
7 – OM3 Enhanced Performance 50μm MM (850/1300nm) 10Gb
8 –  OM4 Enhanced Performance 50μm MM (850/1300nm) 10Gb
9 –  OM1 Enhanced Performance 62.5μm MM (850/1300nm) 10Gb

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
UCTS-001Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access
UCTS-001-BLADEReplacement Blade for UCTS-001
MA-2-REFILLRibbon Matrix Remover with Board & Double Sided Tape (Qty. 25)
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and Up to 3 mm Jacketed Single Fibers
FOS-01Lynx-CustomFit™ Fiber Optic Shears
]]>
Standard Ribbon Interlocking Armored Indoor Plenum Central Tube Cables https://sumitomoelectriclightwave.com/product/standard-ribbon-interlocking-armored-indoor-plenum-central-tube-cables/ Mon, 23 May 2016 20:21:50 +0000 https://www.sumitomoelectric.com/?post_type=product&p=1753

Specifications

General

PropertySpecification
ApplicationIndoor
Cable StructureCentral Tube
Ribbon TypeStandard Ribbon
Metallic ElementsBonding/Grounding Required

Mechanical Characteristics

PropertySpecification
Maximum Tensile Load (During Installation)600 lb (2,670 N)
Maximum Recommended Service Load200 lb (890 N)
Maximum Compression Resistance 124 lb/in (220 N/cm)

Bend Radius

PropertySpecification
During Installation20 x Cable O.D.
After Installation10 x Cable O.D.

Temperature Range

PropertySpecification
Operation+32 to +158°F (0 to +70°C)
Storage & Shipping-40 to +158°F (-40 to +70°C)
Installation+32 to +140°F (0 to +60°C)

Standards

PropertySpecification
StandardsOFNR, FT-6/NFPA 262, OFCP, FT6

Ordering Information

Fiber CountFiber SizeNominal Cable O.D. (in | mm)Nominal Cable Armor O.D. (in | mm)Nominal Weight (lb/kft | kg/km)Fibers Per Ribbon
12 – 96f250 μm0.41 in (10.5 mm)0.68 in (17.3 mm)199.0 lb/kft (298.0 kg/km)12f
108 – 216f250 μm0.55 in (14.0 mm)0.83 in (21.0 mm)267.0 lb/kft (398.0 kg/km)12f
108 – 216f250 μm0.65 in (16.6 mm)0.87 in (22.0 mm)295.0 lb/kft (439.0 kg/km)12f
288 – 432f250 μm0.85 in (21.6 mm)1.15 in (29.3 mm)441.0 lb/kft (656.0 kg/km)24f

Instructions: Create an item number by using this character set & codes.

SE – [ 1 ] RH [ 2 2 2 2 ] – [ 3 ]

[ 1 ] – Fiber Type[ 2 ] – Fiber Count (4-Digits)[ 3 ] – Fiber Attenuation Grades
1 – 50μm Multi-Mode Fiber (OM3/OM4)
8 –  PureAccess® G.657.A1 Bend Insensitive
Single-Mode Fiber
0012 – 12f
0024 – 24f 
0048 – 48f 
0072 – 72f 
0096 – 96f 
0144 – 144f 
0288 – 288f 
0432 – 432f   
B – Standard Single-Mode
0.40/0.30 dB/km (1310/1550 nm)  
7 – OM3 Enhanced Performance
50μm MM (850/1300nm) 10Gb
8 –  OM4 Enhanced Performance
50μm MM (850/1300nm) 10Gb

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
ACS-01Armored Cable Slit & Ring Tool, 0.315 – 1.125 in (8 – 28.6 mm) for End/Mid-Span Access
UCTS-001Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access
ACS-01-BLADEReplacement Blade for ACS-01
UCTS-001-BLADEReplacement Blade for UCTS-001
MA-2-REFILLRibbon Matrix Remover with Board & Double-Sided Tape (Qty. 25)
RS-2424f Ribbon Splitter Tool
JR-7Heated Jacket Remover with AC Adapter & Battery for Single-fibers & up to12-Fiber Ribbons
JR-M03Jacket Remover for 250μm, 900μm, and Up to 3 mm Jacketed Single-fibers
FOS-01Lynx-CustomFit™ Fiber Optic Shears
]]>
Standard Ribbon Indoor/Outdoor Riser Central Tube Cables https://sumitomoelectriclightwave.com/product/indooroutdoor-riser-ribbon-cable/ Thu, 14 Jan 2016 21:05:37 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=369

Specifications

General

PropertySpecification
ApplicationIndoor/Outdoor
Jacket ColorBlack
Jacket MaterialPolyvinyl Chloride (PVC)
Cable StructureCentral Tube
Ribbon TypeStandard Ribbon
Metallic ElementNo Bonding/Grounding Required

Mechanical Characteristics

PropertySpecification
Maximum Tensile Load (During Installation)600 lb (2,670 N)
Maximum Recommended Service Load200 lb (890 N)
Maximum Compression Resistance124 lb/in (220 N/cm)
Minimum Bend Radius (During/After Installation)20/10 x Cable O.D.

Temperature Range

PropertySpecification
Operation-40 to +158°F (-40 to +70°C)
Storage & Shipping-40 to +158°F (-40 to +70°C)
Installation+32 to +140°F (0 to +60°C)

Standards

PropertySpecification
StandardsOFNR, FT4

Ordering Information

Fiber CountFiber SizeNominal Cable O.D. (in | mm)Nominal Weight (lb/kft | kg/km)Fibers Per Ribbon
12 – 48f250 μm0.62 (15.7)138.0 (205.0)12f
60 – 144f250 μm0.69 (17.4)156.0 (231.0)12f

Instructions: Create a part number by using this character set & codes.

SE- [ 1 ] RG [ 2 2 2 2 ] – [ 3 ]

[ 1 ] – Fiber Type[ 2 ] – Fiber Count (4-Digits)[ 3 ] – Fiber Attenuation Grades
8 –  PureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber0012 – 12 Fibers
0024 – 24 Fibers
0036 – 36 Fibers 
0048 – 48 Fibers
0072 – 72 Fibers
0096 – 96 Fibers 
0144 – 144 Fibers  
B – Standard Single-Mode 0.40/0.30 dB/km (1310/1550 nm)

Accessories

Product NameDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CRC-002Cable Slit Tool for End/Mid-Span Access
UCTS-001Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access
UCTS-001-BLADEReplacement Blade for UCTS-001
MA-2-KITRibbon Matrix Remover with Ribbon Splitter Tool (RS-M1), Board, Double-Sided Tape (Qty. 25), and Ribbon Color Code Chart (RCC-001)
MA-2-REFILLRibbon Matrix Remover with Board & Double-Sided Tape (Qty. 25)
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and up to 3 mm Jacketed Single Fibers
FOS-01Lynx-CustomFit™ Fiber Optic Shears
]]>
Standard Ribbon Armored OSP Central Tube Cables https://sumitomoelectriclightwave.com/product/standard-ribbon-armored-osp-central-tube-cables/ Thu, 14 Jan 2016 21:04:28 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=366

Specifications

General
ApplicationOutside Plant
Jacket ColorBlack
Jacket MaterialMedium Density Polyethylene (MDPE)
Cable StructureCentral Tube
Ribbon TypeStandard Ribbon
Metallic ElementsBonding/Grounding Required
Bend Radius
During Installation (Dynamic)20 x Cable O.D.
After Installation (Static)10 x Cable O.D.
Mechanical Characteristics
Maximum Tensile Load (During Installation)600 lb (2,670 N)
Maximum Recommended Service Load200 lb (890 N)
Maximum Compression Resistance248 lb/in (440 N/cm)
Temperature Range
Operation-40°F to +158°F (-40°C to +70°C)
Storage & Shipping-40°F to +167°F (-40°C to +75°C)
Installation-22°F to +140°F (-30°C to +60°C)

Ordering Information

Fiber CountNominal Cable O.D. (in | mm)Nominal Weight (lb/kft | kg/km)Fibers Per Ribbon
12- 48f0.55 (14.0)110.0 (182.0)12f
60 – 96f0.58 (14.7)140.0 (208.0)12f
108 – 144f0.64 (16.2)169.0 (252.0)12f
156 – 216f0.80 (20.4)205.0 (305.0)12f
240 – 288f0.86 (21.9)249.0 (371.0)24f
312 – 432f0.97 (24.6)286.0 (425.0)24f

Instructions: Create a part number by using this character set and codes.

SE – [ 1 ] DB [ 2 2 2 2 ] – [ 3 ]

[ 1 ] – Fiber Type[ 2 ] – Fiber Count (4-Digits)[ 3 ] – Fiber Attenuation Grades
8 – PureAccess® G.657.A1
Bend Insensitive Single-Mode Fiber  
0012 – 12fB – Standard Single-Mode 0.40/0.30 dB/km (1310/1550 nm)
0024 – 24f
0048 – 48f
0072 – 72f
0096 – 96f
0144 – 144f
0216 – 216f
0288 – 288f
0432 – 432f

Accessories

Part NumberDescription
CRC-001Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access
CSC-002Cable Slit Tool for End/Mid-Span Access
ACS-01Armored Cable Slit & Ring Tool, 0.315 – 1.125 in (8 – 28.6 mm) for End/Mid-Span Access
UCTS-001Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access
ACS-01-BLADEReplacement Blade for ACS-01
UCTS-001-BLADEReplacement Blade for UCTS-001
RS-2424f Ribbon Splitter Tool
MA-2-KITRibbon Matrix Remover with Ribbon Splitter Tool (RS-M1), Board, Double-Sided Tape (Qty. 25), and Ribbon Color Code Chart (RCC-001)
MA-2-REFILLRibbon Matrix Remover with Board & Double Sided Tape (Qty. 25)
JR-7Heated Jacket Remover with AC Adapter & Battery for Single Fibers & Up to 12-Fiber Ribbons
JR-M03Jacket Remover for 250 μm, 900 μm, and Up to 3 mm Jacketed Single Fibers
FOS-01Lynx-CustomFit™ Fiber Optic Shears
]]>