Tube Cables https://sumitomoelectriclightwave.com Next Generation Thinking Mon, 12 Jan 2026 17:08:45 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.4 https://sumitomoelectriclightwave.com/wp-content/uploads/2019/08/fav.png Tube Cables https://sumitomoelectriclightwave.com 32 32 Outdoor Enhanced Thermal Stability Tube Cables (Aerial and Duct) https://sumitomoelectriclightwave.com/product/outdoor-enhanced-thermal-stability-tube-cables-aerial-and-duct/ Tue, 26 Jan 2016 19:47:43 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=1095

Specifications

PropertySpecification
ApplicationAerial; Duct
Non-Armored Tube Cables (MSOS Series)Water-Blocked Tube Cable; Low Shrink with 4 Yellow Stripes
Armored Tube Cables (MSOS-2 Series)With Jacketed Interlocked Steel Armor
Operation Temperature Range (ICEA 640)-40°F to +158°F (-40°C to +70°C)
Minimum Bend Radius (During/After Installation)20 / 10 x Cable O.D.
Standard Reel Length3,000 ft (+30 ft / -0 ft)
Maximum Reel Length3,000 ft (+30 ft / -0 ft)
Metallic Elements (Armored Tube Cables Only)Bonding / Grounding Required
M.O.Q. (Armored Tube Cables Only)1,000 ft
Inner Tube I.D. / O.D.6 mm / 8 mm

Ordering Information

Standard Tube Cables – Inventory Products

(2, 7, and 19 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Max Tensile Load (lbs)Std. Length (ft)
TC02MSOS20.81902003,000
TC02MSOS-221.204905003,000
TC07MSOS71.142034003,000
TC07MSOS-271.548746003,000
TC19MSOS191.664446003,000
TC19MSOS-2192.201,6536003,000

Special Order Only Tube Cables – Non-Inventory Products

(4 and 12 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Max Tensile Load (lbs)Std. Length (ft)
TC04MSOS4 (CSM)0.941462003,000
TC04MSOS-24 (CSM)1.345385003,000
TC12MSOS121.513004003,000
TC12MSOS-2121.891,0896003,000
]]>
Outdoor Normal Environment Tube Cables (Duct and Direct Buried) https://sumitomoelectriclightwave.com/product/outdoor-normal-environment-tube-cables-duct-and-direct-buried/ Tue, 26 Jan 2016 19:48:49 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=1097

Specifications

PropertySpecification
ApplicationDuct; Direct Buried
Non-Armored Tube Cables (TOX and TOD Series)Water-Blocked, Dielectric Tube Cables
Armored Tube Cables (TOX-2 and TOD-2 Series)With Jacketed Interlocked Steel Armor
Operation Temperature Range (ICEA 640)-40°F to +158°F (-40°C to +70°C)
Minimum Bend Radius (During/After Installation)20 / 10 x Cable O.D.
Standard Reel Length3,000 ft (except TC24TOX 2,000 ft)
Maximum Reel Length3,000 ft (except TC24TOX 2,000 ft)
Metallic Elements (Armored Tube Cables Only)Bonding / Grounding Required
M.O.Q. (Armored Tube Cables Only)1,000 ft
Inner Tube I.D. / O.D.6 mm / 8 mm

Ordering Information

Standard Tube Cables – Inventory Products

(2, 7, and 19 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Max Tensile Load (lbs)Std. Length (ft)
TC01TOX10.53592003,000
TC02TOX20.81902003,000
TC02TOX-221.204905003,000
TC04TOX4 (CSM)0.941464003,000
TC04TOX-24 (CSM)1.315385003,000
TC07TOX71.142034003,000
TC07TOX-271.508746003,000
TC19TOX191.774445003,000
TC19TOX-2192.101,6966003,000

Special Order Only Tube Cables – Non-Inventory Products

(12 and 14 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Max Tensile Load (lbs)Std. Length (ft)
TC12TOX121.463004003,000
TC12TOX-02121.891,0896003,000
TC24TOX242.006505002,000
]]>
Indoor Riser Rated Tube Cables https://sumitomoelectriclightwave.com/product/indoor-riser-rated/ Tue, 26 Jan 2016 19:49:54 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=1099

Specifications

PropertySpecification
Non-Armored Tube Cables (TRC Series)UL/cUL/OFNR-Rated Tube Cables, Single Jacket
Armored Tube Cables (TRC-1 Series)With Interlocked Galvanized Steel Armor (No Armor Overjacket)
OFNR Riser-RatedUL 1666, cUL FT4, CSA FT4 Listed
Operation Temperature Range-4° F to + 158°F (-20° C to +70° C)
Minimum Bend Radius (During/After Installation)20 / 10 x Cable O.D.
Standard Reel Length3,000 ft (+30 ft / -0 ft)
Maximum Reel Length3,000 ft (+30 ft / -0 ft)
Metallic Elements (Armored Tube Cables Only)Bonding/Grounding Required
M.O.Q. (Armored Tube Cables Only)1,000 ft
Inner Tube I.D. / O.D.6 mm / 8 mm

Ordering Information

Standard Tube Cables – Inventory Products

(2, 7, and 19 Tube Cables Only)

Part NumberTube CountO.D. (in.)Max Weight (lbs/kft)Max Tensile Load (lbs)Standard Length (ft)
TC02TRC20.801401203,000
TC02TRC-121.085435003,000
TC07TRC71.003104003,000
TC07TRC-171.399826003,000
TC19TRC191.705745003,000
TC19TRC-1192.031,7836002,500

Special Order Only Tube Cables – Non-Inventory Products

(4, 12, and 24 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Max Tensile Load (lbs)Standard Length (ft)
TC04TRC4 (CSM)0.902102003,000
TC04TRC-14 (CSM)1.207485003,000
TC12TRC121.484805003,000
TC12TRC-1121.731,1016003,000
TC24TRC242.027935002,000
]]>
Indoor Plenum Rated Tube Cables https://sumitomoelectriclightwave.com/product/indoor-plenum-rated/ Tue, 26 Jan 2016 19:51:45 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=1101

Specifications

PropertySpecification
Non-Armored Tube Cables (TP2 Series)UL/cUL/CSA NFPA 262 Plenum OFNP Tube Cables, Single Jacket
Armored Tube Cables (TP2-1 Series)With Interlocked Galvanized Steel Armor (No Armor Overjacket)
OFNP Plenum-RatedNFPA 262, cUL FT6, CSA FT6 Listed
Operation Temperature Range (Plenum-Rated)+32°F to +158°F (0°C to +70°C)
Minimum Bend Radius (During/After Installation)20 / 10 x Cable O.D.
Standard Reel Length1,000 ft (+10 ft / -0 ft)
Maximum Reel Length1,000 ft (10 ft / -0 ft)
Metallic Elements (Armored Tube Cables Only)Bonding / Grounding Required
M.O.Q. (Armored Tube Cables Only)1,000 ft
Inner Tube I.D. / O.D.5.5 mm / 8 mm

Ordering Information

Standard Tube Cables – Inventory Products

(2, 4, 7, and 19 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Max Tensile Load (lbs)Std Length (ft)
TC02TP220.811201201,000
TC02TP2-121.315595001,000
TC04TP24 (CSM)1.002102001,000
TC04TP2-14 (CSM)1.316085001,000
TC07TP271.404004001,000
TC07TP2-171.508076001,000
TC19TP2191.775745001,000
TC19TP2-1192.151,6966001,000

Special Order Only Tube Cables – Non-Inventory Products

(12 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Max Tensile Load (lbs)Std Length (ft)
TC12TP2121.494805001,000
TC12TP2-1121.691,1006001,000

Resources

Sumitomo Electric Product Specifications
SF-F04-003: TCxxTP2 PLENUM RATED (NFPA 262) JACKETED TUBE CABLE SERIES
SF-F04-004: TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING
Sumitomo Recommended Procedure
SP-F04-003TUBE PRESSURE TESTING PROCEDURE
SP-F04-004TUBE OBSTRUCTION TESTING PROCEDURE
SP-F04-008TUBE CABLE INSTALLATION PROCEDURES
SP-F04-029PLENUM-RATED JACKETED TUBE CABLE TCxxTP2 INSTALLATION PROCEDURE
SP-F04-039ARMORED TUBE CABLE INSTALLATION PROCEDURES
LFI Resource Portal
LFI Resource Portal | Sumitomo Electric Lightwave Corporation
]]>
Indoor/Outdoor LSZH Special Applications Tube Cables https://sumitomoelectriclightwave.com/product/outdoorindoor-special-applications/ Tue, 26 Jan 2016 19:52:58 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=1103

Specifications

PropertySpecification
Non-Armored Tube Cables (MTIO Series)UL/cUL FT4 NFPA 130 Indoor/Outdoor Tube Cables
Armored Tube Cables (MTIO-2 Series)With Interlocked Galvanized Steel Armor LSZH Jacketed
Transit and Passenger Rail SystemsNFPA 130, IEEE 1202, ANSI/UL 1685, UL1666, OFNR, FT-4-ST1
Operation Temperature Range-40°F to +158°F (-40°C to +70°C)
Minimum Bend Radius (During/After Installation)20 / 10 x Cable O.D.
Standard Reel Length3,000 ft (+30 ft / -0 ft)
Maximum Reel Length3,000 ft (+30 ft / -0 ft)
Metallic Elements (Armored Tube Cables Only)Bonding / Grounding Required
M.O.Q. (Armored Tube Cables Only)1,000 ft
Inner Tube I.D. / O.D.6 mm / 8 mm

Ordering Information

Standard Tube Cables – Inventory Products

(2, 7, and 19 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Std Length (ft)
TC02MTIO20.841283,000
TC02MTIO-221.205313,000
TC07MTIO71.143363,000
TC07MTIO-271.501,0013,000
TC19MTIO191.786723,000
TC19MTIO-2192.171,8503,000

Special Order Only Tube Cables – Non-Inventory Products

(4 and 12 Tube Cables Only)

Part NumberTube CountO.D. (in)Max Weight (lbs/kft)Std Length (ft)
TC04MTIO4 (CSM)0.972353,000
TC04MTIO-24 (CSM)1.386233,000
TC12MTIO121.434373,000
TC12MTIO-2121.771,2233,000

Resources

Sumitomo Product Specifications
SF-F04-009: TCxxMTIO & TCxxMTIO-4 INDOOR/OUTDOOR TUBE CABLE SERIES FOR USE IN MASS TRANSIT APPLICATIONS, NUCLEAR PLANTS, CLASS I DIV. 1 & 2 APPLICATIONS – HALOGEN FREE JACKET CABLES
Sumitomo Recommended Procedure
SP-F04-003TUBE PRESSURE TESTING PROCEDURE
SP-F04-004TUBE OBSTRUCTION TESTING PROCEDURE
SP-F04-008TUBE CABLE INSTALLATION PROCEDURES
SP-F04-039ARMORED TUBE CABLE INSTALLATION PROCEDURES
LFI Resource Portal
LFI Resource Portal | Sumitomo Electric Lightwave Corporation
]]>
Unjacketed Single Tubes https://sumitomoelectriclightwave.com/product/unjacketed-single-tubes/ Tue, 26 Jan 2016 19:53:58 +0000 http://208.79.82.171/~sumitomoe/?post_type=product&p=1105

Specifications

PropertySpecification
OFN General Purpose Fire RatedUL 1581, CUL FT1, CSA OFN (FT1) Listed
Operation Temperature Range –General Purpose Rated-4°F to +158°F (-20°C to +70°C)
Minimum Bend Radius for 8 mm OD Single Tubes (During and After Installation)9 in
Minimum Bend Radius for 6 mm OD Single Tubes Single-Tubes6 in
Inner / Outer Tube Diameter6 mm / 8 mm (Except TC01T6M 4.25 mm / 6 mm)

Ordering Information

Part NumberDescriptionOutside Dia. (In.)Max Wgt. (Lbs./Kft.)Max Tensile Load (Lbs.)Std. LengthMax Length
TC01TBXBlack Tube – Non-flame Retardant0.31515603,0003,000
TC01TCXClear Tube – Non-flame Retardant0.31532605003,000
TC01TGXUL/CUL/CSA OFN Rated0.31517601,0003,000
TC01T6MClear Tube – Non-flame Retardant 6 mm OD x 4.25 ID0.23617605003,000
]]>